Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.037
Filter
1.
Rev. gaúch. enferm ; 45: e20230107, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1536378

ABSTRACT

ABSTRACT Objective: To analyze the validity evidence of the Brazilian version of the Cancer Behavior Inventory - Brief Version. Method: Methodological study, conducted between November and December 2021, with 140 patients undergoing hospital cancer treatment in João Pessoa, Paraíba, Brazil. Psychometric analyses were performed in the adapted version, using exploratory factor analysis and correlation with correlated constructs. Results: A two-factor and 10-item model was evidenced. The cumulative variance explained about 61% the shared variance of the items. Satisfactory values were observed for the factors in the analyses of composite reliability (0.89 and 0.91, respectively), internal consistency (0.86 and 0.91, respectively) and ORION (0.89 and 0.85, respectively). The expected correlations of self-efficacy with quality of life (convergent) and with anxiety and depression (divergent) were evident. Conclusion: The Brazilian version of the instrument showed evidence of validity, being considered reliable to assess the self-efficacy of patients undergoing cancer treatment.


RESUMEN Objetivo: Analizar las evidencias de validez de la versión brasileña del Cancer Behavior Inventory - Brief Version. Método: Estudio metodológico, realizado entre noviembre y diciembre de 2021, con 140 pacientes en tratamiento oncológico hospitalario en João Pessoa, Paraíba, Brasil. Se realizaron análisis psicométricos en la versión adaptada, mediante análisis factorial exploratorio y correlación con constructos correlacionados. Resultados: Se evidenció un modelo de 2 factores y 10 ítems. La varianza acumulada explicó alrededor del 61% de la varianza compartida de los ítems. Se observaron valores satisfactorios para los factores en el análisis de confiabilidad compuesta (0,89 y 0,91, respectivamente), consistencia interna (0,86 y 0,91, respectivamente) y ORION (0,89 y 0,85, respectivamente). Se evidenciaron las correlaciones esperadas de la autoeficacia con la calidad de vida (convergente) y con la ansiedad y la depresión (divergente). Conclusión: La versión brasileña del instrumento mostró evidencias de validez, siendo considerado confiable para evaluar la autoeficacia de pacientes en tratamiento oncológico.


RESUMO Objetivo: Analisar as evidências de validade da versão brasileira do Cancer Behavior Inventory - Brief Version. Método: Estudo metodológico, realizado entre os meses de novembro e dezembro de 2021, com 140 pacientes em tratamento oncológico hospitalar em João Pessoa, Paraíba, Brasil. Foram realizadas análises psicométricas na versão adaptada, mediante a análise fatorial exploratória e correlação com constructos correlacionados. Resultados: Evidenciou-se um modelo de 2 fatores e 10 itens. A variância acumulada explicou cerca de 61% da variância compartilhada dos itens. Foram observados valores satisfatórios para os fatores nas análises de confiabilidade composta (0,89 e 0,91, respectivamente), consistência interna (0,86 e 0,91, respectivamente) e ORION (0,89 e 0,85, respectivamente). Evidenciaram-se as correlações esperadas da autoeficácia com a qualidade de vida (convergente) e com a ansiedade e depressão (divergente). Conclusão: A versão brasileira do instrumento mostrou evidências de validade, sendo considerada como confiável para avaliar a autoeficácia dos pacientes em tratamento oncológico.

2.
CoDAS ; 36(1): e20220302, 2024. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1520732

ABSTRACT

RESUMO Objetivo Investigar evidências de validade de construto para um Instrumento de Avaliação Fonológica para o Português Brasileiro, baseadas nos dados de diagnóstico gerados por sua própria aplicação a partir da análise contrastiva e do grau de severidade de fala. Método A amostra foi composta por dados de 176 crianças, com idades entre cinco até nove anos. Foram avaliadas pelo Instrumento de Avaliação Fonológica e classificadas em com transtorno fonológico ou em desenvolvimento fonológico típico, comparando tais resultados aos critérios para o transtorno no DSM-5. A busca por evidências da validade de construto contou com a concordância entre os dois métodos de avaliação, aplicando o Coeficiente Kappa. Para a diferenciação entre os grupos, utilizou-se o teste t de Student para amostras independentes. Buscou-se a investigação dos índices do instrumento pela estatística da Curva de Receiver Operating Characteristic para obter valores de área, ponto de corte, sensibilidade, especificidade, acurácia, valor preditivo positivo e negativo. Resultados O instrumento apresentou concordância e diferenciação significativa entre as classificações. Quanto aos parâmetros de desempenho, exibe ponto de corte para diagnóstico com resultados iguais ou maiores do que 96,17%, excelente valor de área sob a curva, assim como percentuais satisfatórios para as outras análises investigadas. Conclusão O conjunto de dados encontrados indicam evidências para validade de construto do Instrumento de Avaliação Fonológica, apresentando uma contribuição útil e válida ao arsenal de avaliação clínica e de pesquisa envolvendo diagnóstico de Transtorno Fonológico e, com seu resultado de acurácia, contribuiu as propriedades de desempenho dos instrumentos utilizados na Fonoaudiologia.


ABSTRACT Purpose To investigate evidence of construct validity for a Phonological Assessment Instrument for Brazilian Portuguese, based on the diagnostic data generated by its application from contrastive analysis and speech severity. Methods The sample consisted of 176 children, aged between five to nine years old. They were evaluated with the Phonological Assessment Instrument and then classified as having Speech Sound Disorder or in typical phonological development, comparing these results to the criteria described for the disorder in the DSM-5. The search for evidence of construct validity relied on the agreement between the two assessment methods while applying the Kappa Coefficient. To differentiate between groups, Student's t-test was used for independent samples. We sought to investigate the instrument indexes using the Receiver Operating Characteristic Curve statistics to obtain values for area, cut-off point, sensitivity, specificity, accuracy, and positive and negative predictive value. Results The instrument showed agreement and significant differentiation between the classifications. As for the performance parameters, it shows a cut-off point for diagnosis with results equal to or greater than 96.17%, an excellent area under the curve, as well as satisfactory percentages for the other analyses investigated. Conclusion The data indicated evidence for the construct validity of the Phonological Assessment Instrument, presenting a useful and valid contribution to the arsenal of clinical assessment and research involving the diagnosis of Speech Sound Disorder and, with its accuracy result, contributed to the properties of performance of instruments used in Speech, Language and Hearing Sciences.

3.
CoDAS ; 36(2): e20220324, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1520736

ABSTRACT

RESUMO Objetivo evidenciar validade de conteúdo e validade de processos de resposta de um instrumento destinado à avaliação fonológica de crianças. Método validade realizada em duas etapas por dois diferentes grupos de juízes, grupo de especialistas e grupo de não-especialistas. O primeiro grupo composto por três juízes especialistas avaliaram os 123 itens lexicais após a elaboração do instrumento, julgando a aplicabilidade das figuras no contexto da avaliação infantil e sugerindo ajustes para compor o conteúdo. A partir das observações, o instrumento foi adequado e direcionado ao grupo de juízes não-especialistas que, por meio da aplicação do instrumento, tiveram suas respostas avaliadas conforme a facilidade ou dificuldade de elicitação dos itens do instrumento. Resultados As avaliações obtiveram resultados de teor positivo para as validades de conteúdo e de processos de resposta. Conclusão o estudo permitiu aprimorar os itens de teste de forma mais criteriosa, beneficiando o uso clínico e científico.


ABSTRACT Purpose to demonstrate the validity of content and the validity of response processes of an instrument intended for the phonological assessment of children. Methods validation was carried out in two stages by two different groups of judges, a group of specialists and a group of non-specialists. The first group, composed of three expert judges, evaluated the 123 lexical items after creating the instrument, judging the applicability of the figures in the context of child assessment, and suggesting adjustments to compose the content. From the observations, the instrument was adapted and directed to the group of non-specialist judges who, through the application of the instrument, had their responses evaluated according to the ease or difficulty of eliciting the instrument's items. Results The predictions obtained positive results for content validity and response processes. Conclusion the study allowed to improve the test items more judiciously, benefiting clinical and scientific use.

4.
Clinics ; 79: 100316, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528430

ABSTRACT

Abstract Objectives: This experimental study focused on the intra- and inter-rater reproducibility of vertical bone level (VBL) measurements at strategic mini-implants (MI) using digital panoramic radiographs (PR). Study design: VBLs of 152 MIs for removable partial denture stabilization at 50 randomly chosen PRs from a clinical trial were digitally evaluated by three ratters. Rater deviations exceeding 0.5 mm were re-examined. The intra-class correlation coefficient (ICC) was applied to estimate reliability. The smallest detectable change (SDC) was interrelated to the minimal clinically important change of 0.2 mm. Results: The first measurement round revealed intra- and inter-rater ICCs of > 0.8. However, 28 sites (9 %) were unreadable, and 97 sites (32 %) revealed differences between observers of ≥ 0.5 mm. Following a consensus session and re-training, an additional 8 sites were excluded and all remaining VBL differences were ≤ 0.5 mm. Thus, the SDCs with 95 % credibility were improved from 0.73 to 0.31 mm in the intra-rater and from 1.52 to 0.34 mm in the interrater statistics. Given a 50 % credibility for this special setting, both the intra- and inter-rater SDCs were 0.11 mm. Conclusions: Digital PR can be reliably utilized to determine VBLs around MIs under conditions of at least two trained observers, mutual calibration sessions, and exclusion of unquantifiable radiographs. German Clinical Trials Register ID:DRKS00007589, www.germanctr.de

5.
Arq. neuropsiquiatr ; 82(2): s00441779297, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550050

ABSTRACT

Abstract Background StepWatch Activity Monitor (SAM) is used to measure the mobility of chronic hemiparetic patients and the Life Space Assessment (LSA) scale was developed to assess the displacement of hemiparetic patients in different contexts through self-reporting. Studies that apply the LSA remotely and correlate it with the number of steps measured by the SAM were not found. Objective To evaluate the measurement properties of the LSA applied remotely and to evaluate the correlation between the LSA scale score and the number of steps measured by the SAM in post-stroke chronic hemiparetic patients. Methods Nineteen patients participated in the study. The LSA scale was applied remotely and later, face to face. The SAM measured the steps taken by the participants over a period of three consecutive days. The correlation between the LSA and the SAM was performed using Pearson's correlation. The measurement properties calculated of remote LSA were the intraclass correlation coefficient (ICC), Cronbrach's alpha, standard error of measurement (SEM), and smallest real difference (SRD). Results The reproducibility of the LSA scale between remote and face-to-face applications was considered excellent with ICC = 0.85 (IC 95% 0.62-0.94); SEM = 8.4; SRD = 23.2, and Cronbach's alpha = 0.85. The correlation between SAM and LSA was positive, considered moderate (r = 0.51) and significant (p = 0.025). Conclusion The LSA is a reproducible measure for post-stroke chronic hemiparetic patients even if applied remotely and can be used as a remote measurement for mobility in a real-world environment for people with chronic hemiparesis after stroke.


Resumo Antecedentes O StepWatch Activity Monitor (SAM) é utilizado para medir a mobilidade de pacientes hemiparéticos crônicos e a escala Life Space Assessment (LSA) avalia o deslocamento de pacientes hemiparéticos em diferentes contextos por meio de autorrelato. Não foram encontrados estudos que tenham aplicado a LSA remotamente nem que a correlacionam com o número de passos mensurados pelo SAM. Objetivo Avaliar as propriedades de medida da LSA aplicada remotamente e avaliar a correlação entre o escore da escala LSA e o número de passos mensurados pelo SAM em pacientes com hemiparesia crônica pós-AVC. Métodos Dezenove participantes responderam a LSA remotamente e, posteriormente, presencialmente. O SAM mediu os passos dados pelos participantes durante um período de três dias consecutivos. A correlação entre a LSA e o SAM foi realizada por meio da correlação de Pearson. As propriedades de medida calculadas da LSA aplicada remotamente foram o coeficiente de correlação intraclasse (ICC), alfa de Cronbrach, erro do padrão de medida (SEM) e menor diferença real (SRD). Resultados A reprodutibilidade da escala LSA entre as aplicações remotas e presenciais foi considerada excelente com ICC = 0,85 (IC 95% 0,62-0,94); SEM = 8,4; SRD = 23,2 e alfa de Cronbrach = 0,85. A correlação entre SAM e a LSA foi positiva, considerada moderada (r = 0,51) e significativa (p= 0,025). Conclusão A LSA é uma medida reprodutível para pacientes hemiparéticos crônicos pós-AVC mesmo se aplicada remotamente e pode ser usada como uma medida remota de mobilidade em ambiente real para pessoas com hemiparesia crônica após AVC.

6.
Fisioter. Mov. (Online) ; 37: e37111, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1550259

ABSTRACT

Abstract Introduction Individuals with autistic spectrum disorder (ASD) have motor impairments that precede communi-cation and socialization disorders. Evaluative instruments compatible with the real possibilities and specificities of patients with ASD, and who quantitatively and qualitatively translate the data in which is wished to intervene with therapeutic actions, are important both in the scope of research and in the clinical evaluation of physiotherapists. Objective To test the interobserver and intraobserver reproducibility of the instrument "Gross Motor Assessment of Children and Adolescents with Autism Spectrum Disorder" (GMA-AUT checklist). Methods The sample consisted of 34 individuals with ASD, aged between 6 and 18 years. The interobserver reproducibility was performed in a blinded manner by two physiotherapists experts in the ASD area of treatment. Intraobserver reproducibility was performed by one of the evaluators on two different days, with a gap of seven days and without access to data from the first evaluation. To verify the reproducibility, percentage of agreement and kappa statistics (k) were used, with the weighted kappa and, for the instrument scores, the intraclass correlation coefficient (ICC). Results The GMA-AUT checklist showed excellent intraobserver agreement, with k ≥ 0.75 and ICC > 0.75. Interobserver reproducibility ranged from good to sufficient agreement with k between 0.40 and 0.75 and ICC > 0.75 for the most part. Conclusion The GMA-AUT checklist had excellent intraobserver reproducibility and, therefore, can be reliably used for assessments of individuals aged between 6 and 18 years with ASD.


Resumo Introdução Indivíduos com transtorno do espectro autista (TEA) apresentam comprometimentos motores que precedem os distúrbios de comunicação e socialização. Instrumentos avaliativos compatíveis com as reais possibilidades e especi-ficidades dos pacientes com TEA, e que traduzam quantitativa e qualitativamente os dados nos quais se deseja intervir com ações terapêuticas, são importantes tanto no âmbito da pesquisa quanto na avaliação clínica do fisioterapeuta. Objetivo Testar a reprodutibilidade interobservador e intraobservador do instrumento "Avaliação Motora Grossa de Crianças e Adolescentes com Transtorno do Espectro Autista" (checklist GMA-AUT). Métodos A amostra foi composta por 34 indivíduos com TEA, com idade entre 6 e 18 anos. A repro-dutibilidade interobservador foi realizada de forma cega por dois fisioterapeutas especialistas na área de tratamento do TEA. A reprodutibilidade intraobservador foi realizada por um dos avaliadores em dois dias distintos, com intervalo de sete dias e sem acesso aos dados da primeira avaliação. Para verificar a reprodutibilidade foram utilizadas a porcentagem de concordância e a estatística kappa (k), com kappa ponderado e, para os escores do instrumento, coeficiente de correlação intraclasse (CCI). Resultados O checklist GMA-AUT apresentou excelente concordância intraobservador, com k ≥ 0,75 e ICC > 0,75. A reprodutibilidade interobservador variou de boa a suficiente concordância, com k entre 0,40 e 0,75 e ICC > 0,75 na maior parte. Conclusão O checklist GMA-AUT apresentou excelente reprodutibilidade intraobservador e, portanto, pode ser utilizado de forma confiável para avaliações de indivíduos com idade entre 6 e 18 anos com TEA.

7.
Article in English | LILACS-Express | LILACS | ID: biblio-1550677

ABSTRACT

ABSTRACT Objective: The current study aimed to translate the Hammersmith Infant Neurological Examination (HINE) into Brazilian Portuguese and analyze the reliability of the translated version for a population of Brazilian infants. Methods: This was a methodological study, approved by the Ethics Committee, carried out between June 2020 and May 2021. HINE is a standardized clinical neurological examination used for the early detection of cerebral palsy. The quantitative section, "neurological examination", contains 26 items scored from 0 to 3 points, divided into five categories: cranial nerve function, posture, movements, muscle tone and reflexes, and reactions. The HINE translation followed four steps: translation, synthesis, back-translation, and evaluation by an expert committee. To verify the reliability of the HINE-Br (Portuguese-Brazil version) two independent examiners evaluated 43 infants, between 3 and 22 months of age. Internal consistency was verified by Cronbach's Alpha coefficient and interrater reliability by the intraclass correlation coefficient (ICC). Results: The translated version was similar to the original version and a few semantic and idiomatic adjustments were necessary. Appropriate internal consistency (Alpha=0.91) was found for the 26 items of the HINE-Br, as well as strong interrater reliability for the total score (ICC2.1=0.95), and also for the five categories (ICC2.1=0.83-0.95). Conclusions: The HINE-Br presents adequate rates of internal consistency and interrater reliability, and can be used for the evaluation of children at risk for cerebral palsy, between 3 and 24 months of age, by pediatricians and pediatric physical therapists.


RESUMO Objetivo: Traduzir o Hammersmith Infant Neurological Examination (HINE) para o português brasileiro e analisar a confiabilidade da versão traduzida em lactentes brasileiros. Métodos: Estudo metodológico, aprovado por Comitê de Ética, realizado entre junho de 2020 e maio de 2021. O HINE é um exame clínico neurológico padronizado, utilizado para detecção precoce de paralisia cerebral. A seção quantitativa, "exame neurológico", contém 26 itens pontuados de 0 a 3, divididos em 5 categorias: função dos nervos cranianos; postura; movimentos; tônus muscular e reflexos; e reações. A tradução do HINE seguiu quatro etapas: tradução; síntese; retrotradução; e avaliação por um comitê de especialistas. Dois examinadores independentes avaliaram 43 lactentes, entre 3 e 22 meses, utilizando a versão HINE-Br (versão em português brasileiro), para verificar sua confiabilidade. A consistência interna foi verificada pelo coeficiente Alpha de Cronbach e a confiabilidade interexaminadores pelo coeficiente de correlação intraclasse (CCI). Resultados: A versão traduzida foi semelhante à versão original e poucos ajustes semânticos e idiomáticos foram necessários. Encontrou-se consistência interna adequada (Apha=0,91) para os 26 itens do HINE-Br, bem como forte confiabilidade interexaminadores para o escore total (CCI2,1=0,95) e também para as cinco categorias (CCI2,1=0,83-0,95). Conclusões: O HINE-Br apresenta índices adequados de consistência interna e confiabilidade interexaminadores, podendo ser utilizada para avaliação de crianças com risco de apresentar paralisia cerebral, entre 3 e 24 meses de idade, por pediatras e fisioterapeutas infantis.

8.
São Paulo med. j ; 142(2): e2022444, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1450520

ABSTRACT

ABSTRACT BACKGROUND: Precisely determining the aspects related to an instrument's validity and reliability measures allows for greater assurance of the quality of the results. OBJECTIVES: To analyze the psychometric properties of The Providers Survey in the Brazilian context of mental health services. DESIGN AND SETTING: The instrument validation study was conducted in Montes Claros, Minas Gerais, Brazil. METHODS: The validation study was conducted using the Consensus-based Standards for the Selection of Health Measurement Instruments checklist to analyze its validity and reliability. RESULTS: A committee of expert judges performed content validation after which the Content Validity Index was calculated. Construct validation took place through Exploratory Factor Analysis using the Kaiser-Meyer-Olkin Test criterion and Bartlett's Sphericity Test. Reliability was verified using test-retest reliability. The significance level adopted for the statistical tests was 5% (P < 0.05). The final instrument comprised 54 questions. The Content Validity Index was 97%. Exploratory Factor Analysis identified a Kaiser-Meyer-Olkin index of 0.901 and Bartlett's Sphericity Test with P < 0.001. We obtained a Cronbach's alpha coefficient of 0.95 and an intraclass correlation coefficient of 0.849. CONCLUSIONS: The Providers Survey, translated and adapted into Portuguese, was named the Work Assessment Instrument for the Recovery of Mental Health. It presented adequate psychometric properties for evaluating work-related practices for the recovery of psychosocial care network users.

9.
Rev. cuba. estomatol ; 60(4)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1550854

ABSTRACT

Introducción: La incorporación de modelos digitales ofrece al ortodoncista una alternativa a los modelos de estudio de yeso que se utilizan habitualmente. Estos son un componente estándar de los registros de ortodoncia y son fundamentales para el diagnóstico y la planificación del tratamiento. No obstante, es importante indagar sobre la confiabilidad de las nuevas tecnologías. Objetivo: Evaluar la reproducibilidad de las medidas digitales y manuales de alineación dental en modelos iniciales de pacientes de ortodoncia. Métodos: Se realizó un estudio de evaluación de tecnología diagnóstica, con 80 modelos de yeso, que fueron digitalizados con el escáner Ineos X5. Una vez obtenidos los modelos en yeso y sus imágenes digitales, el investigador que obtuvo el mejor resultado en la calibración inter e intra examinador realizó la medición de la alineación dental. Las medidas manuales se tomaron con un calibrador digital, y las digitales fueron tomadas en el software Nemocast. El análisis incluyó el cálculo del coeficiente de correlación intraclase (CCI) y los límites de acuerdo de Bland y Altman. Un valor de p < 0,05 fue considerado como estadísticamente significativo. Resultados: Los valores de CCI oscilaron entre 0,643 y 0,874. Más de la mitad de las mediciones obtuvieron valores de CCI superiores a 0,81, lo que se consideró una reproducibilidad "casi perfecta", según la interpretación sugerida por Landis y Koch. Se obtuvo un promedio de las diferencias entre -0,2 a -0,4, con límites de acuerdo estrechos. Conclusiones: Se encontró una reproducibilidad "casi perfecta" y un promedio de las diferencias cercano a cero entre las medidas manuales y digitales.


Introduction: The incorporation of digital models offers the orthodontist an alternative to the plaster study models that are commonly used. These are a standard component of orthodontic records and are critical to diagnosis and treatment planning. It is important to inquire about the reliability of new technologies. Objective: To evaluate the reproducibility of digital and manual measurements of dental alignment in initial models of orthodontic patients. Methods: A diagnostic technology evaluation study was carried out with 80 plaster models that were digitized with the Ineos X5 Scanner. Once the plaster models and digital images of them were obtained, the researcher who obtained the best result in the inter and intra examiner calibration performed the dental alignment measurement. Manual measurements were taken with a digital caliper, and digital ones were taken in the Nemocast software. The analysis included the calculation of the Intraclass Correlation Coefficient (ICC) and the Bland and Altman limits of agreement. A value of p <0.05 was considered statistically significant. Results: ICC values ​​ranged between 0.643 and 0.874, more than half of the measurements obtained ICC values ​​higher than 0.81, which was considered "almost perfect" reproducibility according to the interpretation suggested by Landis and Koch. Differences between -0.2 to -0.4 were averaged with narrow limits of agreement. Conclusions: An "almost perfect" reproducibility was found and an average of the differences close to zero between manual and digital measurements.

10.
Arch. cardiol. Méx ; 93(3): 267-275, jul.-sep. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1513579

ABSTRACT

Resumen Introducción: La confiabilidad de la presión sistólica arterial pulmonar por ecocardiografía transtorácica se encuentra limitada por su variabilidad para definir la hipertensión pulmonar. Objetivo: Conocer la variabilidad en la presión sistólica arterial pulmonar estimada por ecocardiografía en la hipertensión pulmonar. Métodos: En el periodo 2016-2020 se captaron sujetos con hipertensión pulmonar que tuvieron estimada la presión sistólica de la arteria pulmonar por ecocardiografía transtorácica y por cateterismo cardiaco derecho. Se obtuvieron sus variables demográficas. Los datos se analizaron con el estadístico descriptivo de Bland-Altman y el coeficiente de correlación intraclase (intervalo de confianza al 95%). Resultados: Se estudiaron 152 sujetos, edad 60 ± 12 años. Índice de masa corporal 27.64 ± 4.69 kg/m2. La presión sistólica de la arteria pulmonar por ecocardiografía transtorácica 58.99 ± 18.62 vs. cateterismo cardiaco 55.43 ± 16.79. Diferencia media (sesgo) -3.6 (29.1, -36.2) y coeficiente de correlación intraclase 0.717 (0.610, 0.794). Conclusiones: La variabilidad es amplia y el acuerdo es sustancial con la presión sistólica de la arteria pulmonar. Se aconseja estimarla solo como tamizaje de la hipertensión pulmonar.


Abstract Introduction: The reliability of pulmonary arterial systolic pressure by transthoracic echocardiography is limited by its variability to define pulmonary hypertension. Objective: To know the variability of pulmonary arterial systolic pressure estimated by echocardiography in pulmonary hypertension. Their demographic variables were obtained. Methods: From 2016-2020 subjects with pulmonary hypertension were recruited, with pulmonary artery systolic pressure estimated by transthoracic echocardiography and by right heart catheterization. Data were analyzed using the Bland-Altman descriptive statistic and the intraclass correlation coefficient (95% confidence interval). Results: 152 subjects, age 60 ± 12 years, were studied. Body mass index 27.64 ± 4.69 kg/m2. The pulmonary artery systolic pressure estimated by transthoracic echocardiography 58.99 ± 18.62 vs. cardiac catheterization 55.43 ± 16.79 mmHg. Mean difference (bias) -3.6 (29.1, -36.2) and intraclass correlation coefficient 0.717 (0.610, 0.794). Conclusions: Variability is wide, and agreement is substantial for pulmonary artery systolic pressure. It is recommended to estimate only as screening for pulmonary hypertension.

11.
Hacia promoc. salud ; 28(1)jun. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534530

ABSTRACT

Introducción: es fundamental garantizar que los instrumentos de medición al ser usados en contextos distintos a los que fueron desarrollados se ajusten en su lenguaje y compresibilidad; el cuestionario principal usado en el estudio PLATINO, en el cual se estableció la prevalencia de enfermedad pulmonar obstructiva crónica en áreas metropolitanas de Latinoamérica por la Asociación Latinoamericana del Tórax, sin incluir población colombiana. Objetivo: realizar validación facial, confiabilidad y comprensibilidad del cuestionario principal usado en el estudio PLATINO para la identificación de personas sin enfermedad respiratoria en Colombia, 2021. Metodología: estudio psicométrico que incluyó validez facial por juicio de expertos, prueba de compresibilidad y confiabilidad; la validación facial valoró la coherencia, relevancia y pertinencia de cada ítem, la aplicación del instrumento se hizo en prueba preliminar de compresibilidad, tras la cual se calculó su confiabilidad. Resultados: la validación facial obtuvo concordancia alta, requiriendo mejoras en redacción del instrumento (Kappa de Fleiss: 0,8569; p=0,000). De los 88 participantes, la mayoría eran hombres (n: 75; 85 %), con edad promedio de 23 años (DS: 6,8), el 25 % con antecedentes de enfermedad pulmonar y el 21 % de tabaquismo. La versión ajustada del cuestionario obtuvo una comprensibilidad global del 94 % y un alfa de Cronbach de 0,82. Conclusiones: se obtiene una versión abreviada y adaptada del cuestionario principal usado en el estudio PLATINO para la identificación de personas sanas respiratorias en población colombiana, con adecuadas propiedades psicométricas en términos de su validación facial, su confiabilidad y su comprensibilidad.


Introduction: It is essential to guarantee that the measurement instruments, when used in contexts other than those in which they were developed, adjust in their language and comprehensibility. The main questionnaire used in the PLATINO study was developed to establish the prevalence of Chronic Obstructive Pulmonary Disease in metropolitan areas of Latin America by the Latin American Thorax Association, without including the Colombian population. Objective: To perform face validity, reliability and comprehensibility of the main questionnaire used in the PLATINO study for the identification of people without respiratory disease in Colombia, 2021. Materials and methods: Psychometric study that included face validity by expert judgment, compressibility and reliability test. The face validity valued the coherence, relevance and pertinence of each item. The application of the instrument was made in a preliminary compressibility test after which its reliability was calculated. Results: Face validity obtained high concordance requiring improvements in the writing of the document (Fleiss Kappa: 0,8569; p=0,000). Ofthe 88 participants, the majority were men (n: 75; 85%) with a mean age of 23 years (SD: 6.8), 25% with a history of lung disease and 21% with a history of smoking. The adjusted version of the questionnaire obtained a global comprehensibility of 94% and a Cronbach's alpha of 0.82. Conclusions: An abbreviated and adapted version of the main questionnaire used in the PLATINO study for the identification of respiratory healthy people in the Colombian population was obtained with adequate psychometric properties in terms of its face validity, reliability and comprehensibility.


Introdução: é fundamental garantir que os instrumentos de medição ao ser usados em contextos diferentes aos que foram desenvolvidos se adequam em sua linguagem e compressibilidade; o questionário principal usado no estudo PLATINO se desenvolveu para estabelecer a prevalência de doença pulmonar obstrutiva crónica em áreas metropolitanas de Latino américa pela Associação Latino-americana do Tórax, sem incluir população colombiana. Objetivo: realizar validação facial, confiabilidade e compreensibilidade do questionário principal usado no estudo PLATINO para a identificação de pessoas sem doença respiratória na Colômbia, 2021. Metodologia: estudo psicométrico que inclui validez facial por juízo de expertos, teste de compressibilidade e confiabilidade; a validação facial valorou a coerência, relevância e pertinência de cada item, a aplicação do instrumento se fez em teste preliminar de compressibilidade, pela qual se calculou sua confiabilidade. Resultados: a validação facial obteve concordância alta, requirindo melhoras em redação do instrumento (Kappa de Fleiss: 0,8569; p=0,000). Dos 88 participantes, a maioria eram homens (n:75; 85 %), com idade média de 23 anos (DS: 6,8), o 25 % com antecedentes de doença pulmonar e o 21 % de tabaquismo. A versão ajustada do questionário obteve uma compreensibilidade global do 94 % e um alfa de Cronbach de 0,82. Conclusões: Obteve-se uma versão abreviada e adaptada do questionário principal usado no estudo PLATINO para a identificação de pessoas sanas sem doenças respiratórias na população colombiana, com adequadas propriedades psicométricas em termos de sua validação facial, sua confiabilidade e sua compreensibilidade.

12.
Conscientiae Saúde (Online) ; 22: e23446, 01 jun. 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1552280

ABSTRACT

Introdução: A eletromiografia (EMG) tem sido utilizada para avaliar alterações no sistema mastigatório proporcionada pela disfunção temporomandibular (DTM). Objetivos: Verificar a confiabilidade teste-reteste de um protocolo de coleta do sinal EMG do músculo masseter em indivíduos com DTM. Métodos: Estudo transversal composto por 20 indivíduos com DTM. Os testes foram realizados em duas sessões com 7 dias de intervalo. O sinal EMG foi avaliado pelas variáveis integral (iEMG) e a raiz quadrada da média do sinal (RMS). Resultados: Na análise intradia a confiabilidade para o RMS (ICC2,k: 0.85 a 0.96 ) e iEMG ICC2,k: 0.85 a 0.95) foi excelente, enquanto que a confiabilidade teste/reteste foi pobre para ambas as variáveis RMS (ICC2,1: 0.03 a 0.29) e iEMG (ICC2,1: 0.08 a 0.39). Conclusões: O protocolo de coleta do sinal EMG do músculo masseter em indivíduos com DTM demonstrou que os dados são reprodutíveis somente na mesma sessão de coletas enquanto que, para coletas em dias alternados a confiabilidade foi pobre.


Introduction: Electromyography (EMG) has been used to assess alterations in the masticatory system caused by temporomandybular disorders (TMD). Objectives: The aim of this study was to verify the test-retest reliability of a protocol for recording the EMG signal from masseter muscle in TMD patients. Methods: This is a cross-sectional study comprising 20 individuals with TMD. Tests were performed in two sessions 7 days apart. The EMG signal was evaluated by the variables integral (iEMG) and the root mean square of the signal (RMS). Results: In the intraday analysis the reliability for the RMS (ICC2,k: 0.85 to 0.96) and iEMG (ICC2,k: 0.85 to 0.95) was excellent, while the test/retest reliability was poor for both RMS (ICC2,1: 0.03 to 0.29) and iEMG (ICC2,1: 0.08 to 0.39) variables. Conclusions: The protocol for collecting the EMG signal from the masseter muscle in an individual with TMD demonstrated that the data are reproducible only in the same recording session, whereas for c recording on alternate days, the reliability was poor.

13.
Rev. cienc. salud (Bogotá) ; 21(2): [1-16], 20230509.
Article in Spanish | LILACS | ID: biblio-1510538

ABSTRACT

Introducción: disponer de instrumentos reproducibles que midan la actividad física y los comportamientos sedentarios es una prioridad para la vigilancia y promoción de estilos de vida saludables en niños y niñas. En esta investigación se evaluó la reproducibilidad prueba-reprueba del cuestionario POIBA-¿Cómo nos movemos? en escolares colombianos. Materiales y métodos: participaron 125 estudian- tes de tercer grado de primaria de una institución educativa colombiana. En dos ocasiones se aplicó el cuestionario POIBA-¿Cómo nos movemos?, que evalúa la actividad física realizada para transportarse a la institución educativa y desde esta, durante el tiempo escolar (clases de educación física y recreo), extraescolar (deportiva, con entrenador) y libre. Se emplearon índices kappa y kappa ponderado en los ítems categóricos y el coeficiente de correlación intraclase con modelo de efectos mixtos en los ítems con escala cuantitativa. Resultados: en los ítems sobre actividad física en el ámbito escolar y deportivo predominaron kappas superiores a 0.70. Las preguntas sobre el transporte a la institución educativa y desde esta tuvieron coeficientes kappa cercanos a 0.90. Los ítems de tiempo frente a pantallas alcanzaron coeficientes kappa alrededor de 0.5, y los correspondientes a la hora de acostarse y levantarse obtuvieron coeficientes de correlación intraclase entre 0.40 y 0.72. Conclusiones: el cuestionario POIBA-¿Cómo nos movemos? es una opción para evaluar la actividad física de escolares en el contexto latinoamericano. Los ítems sobre actividad física de transporte, en el ámbito escolar y deportivo, tuvieron los mayores índices de reproducibilidad.


Introduction: Reproducible instruments measuring physical activity and sedentary behaviors are a priority for monitoring and promoting healthy lifestyles for boys and girls. This study evaluated the test-retest reproducibility of the "Prevención de la Obesidad Infantil en Barcelona (Childhood Obesity Prevention in Barcelona) [POIBA]-How do we move?" questionnaire in Colombian school children. Materials and methods: One hundred twenty-five third-grade primary students from a public educational institution in Colombia participated in the "POIBA-How do we move?" questionnaire, which was conducted twice. The survey measured physical activity during travel to and from school, school hours (physical education classes and recess), extracurricular activities (sports with a coach), and leisure time. To assess reproducibility, categorical questions and questions with a quantitative scale were evaluated using kappa and weighted kappa indices and an intraclass correlation coefficient with a mixed-effects model. Results: In the questions about physical activity at school and sports practice, kappas higher than 0.70 predominated. The questions about commuting to and from school had kappa coefficients close to 0.90. The kappa coefficients for the screen-time questions were around 0.5, and the intraclass correlation coefficients for questions about going to bed and getting up were between 0.40 and 0.72. Conclusions: The "POIBA-How do we move?" questionnaire is a valuable tool for evaluating the physical activity of school children in a Latin American context. The questions concerning physical activity during commuting to and from school, school hours, and sports environment had the highest reproducibility indices.


Introdução: dispor de instrumentos reprodutíveis que meçam a atividade física e os comportamentos sedentários é uma prioridade para a monitorização e promoção de estilos de vida saudáveis em meninos e meninas. Nesta pesquisa, a reprodutibilidade teste-reteste do Questionário POIBA ­ (como nos movemos?) foi avaliada em estudantes colombianos. Materiais e métodos: participaram do estudo 125 alunos da terceira série do ensino fundamental de uma instituição educacional colombiana. Foi aplicado o questionário POIBA ­ (como nos movemos?) em dois momentos, que avalia a atividade física realizada para o transporte de e para a instituição de ensino, no horário escolar (aulas de educação física e recreio), extracurricular (esportes, com treinador) e no tempo livre. Para avaliar a reprodutibi- lidade, foram utilizados os índices Kappa e Kappa ponderado para itens categóricos e o coeficiente de correlação intraclasse com modelo de efeitos mistos para itens com escala quantitativa. Resultados: nos itens sobre atividade física no ambiente escolar e esportivo predominaram Kappas superiores a 0.70. As questões sobre transporte de ida e volta para a instituição de ensino apresentaram coeficientes Kappa próximos a 0.90. Os itens tempo de tela atingiram coeficientes Kappa em torno de 0.5, e os correspondentes a hora de dormir e acordar obtiveram coeficientes de correlação intraclasse entre 0.40 e 0.72. Conclusões: o questionário POIBA ­ (como nos movemos?) é uma opção para avaliação da atividade física de estudantes no contexto latino-americano. Os itens sobre atividade física de transporte, no ambiente escolar e esportivo apresentaram os maiores índices de reprodutibilidade


Subject(s)
Humans , Child
14.
Ciênc. Saúde Colet. (Impr.) ; 28(4): 1073-1086, abr. 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1430168

ABSTRACT

Abstract The study aimed to evaluate relative validity and reproducibility of seven WHO indicators of dietary practices in children aged 6-23.9 months. Data from probabilistic sample of children who used primary healthcare services in Rio de Janeiro, Brazil were collected using a 24h dietary recall (24HR) and a closed questionnaire (Q1) on feeding in the day before the study. The last one was reapplied (Q2) around 16 days later. Validity was assessed by comparing the prevalence rates estimated by 24HR and Q1 and calculating the positive (PPV) and negative (NPV) predictive values, sensitivity (Se), specificity (Sp), and accuracy index (AI) for the resulting indicators. For reproducibility, estimated prevalence rates based on Q1 and Q2 were compared and the kappa index and prevalence-adjusted bias-adjusted kappa were estimated. Of the seven estimated indicators, the prevalence of two was overestimated (Continued breastfeeding: 50.0% vs 40.0%; Sweet beverage consumption: 65.1% vs 52.7%) and the prevalence of one was underestimated (Zero vegetable or fruit consumption: 6.5% vs 18.1%). For most indicators, Se and PPV were higher than Sp and NPV. The prevalence rates determined with Q1 and Q2 were similar for 6 indicators. More than half showed good, very good or excellent agreement.


Resumo O estudo avaliou a validade relativa e a reprodutibilidade de sete indicadores da OMS sobre alimentação de crianças de 6-23,9 meses. Dados de amostra probabilística de usuários de serviços básicos de saúde na cidade do Rio de Janeiro, Brasil, foram coletados por meio de recordatório alimentar de 24 horas (R24h) e questionário fechado (Q1) sobre alimentação no dia anterior ao estudo. Este último foi reaplicado (Q2) em torno de 16 dias depois. A validade foi avaliada comparando-se as prevalências estimadas pelo R24h e Q1 e calculando-se os valores preditivos positivo (VPP) e negativo (VPN), sensibilidade (Se), especificidade (Esp) e índice de acurácia (IA) dos indicadores resultantes. Para reprodutibilidade, as prevalências estimadas com base em Q1 e Q2 foram comparadas e estimados o índice kappa e o kappa ajustado pela prevalência. Dos sete indicadores estimados, houve superestimação da prevalência de dois (aleitamento continuado: 50,0% versus 40,0%; consumo de bebidas adoçadas: 65,1% vs. 52,7%) e subestimação da prevalência de um (não consumo de frutas e hortaliças: 6,5% vs. 18,1%). Para a maioria deles, Se e VPP foram maiores do que Esp e VPN. As prevalências determinadas com Q1 e Q2 foram semelhantes para seis indicadores. Mais da metade dos indicadores apresentaram concordância boa, muito boa ou excelente.

15.
São Paulo med. j ; 141(2): 114-119, Mar.-Apr. 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1424669

ABSTRACT

ABSTRACT BACKGROUND: The Hip Sports Activity Scale (HSAS) is a hip-specific instrument for assessing the present levels of physical activity among patients with femoroacetabular impingement (FAI) syndrome. When evaluating treatment outcomes in patients with FAI syndrome, it is necessary to use joint-specific instruments and ones that can evaluate the levels of physical activity in these patients, such as the HSAS-Brazil. OBJECTIVE: To validate the HSAS-Brazil among a group of physically active patients after arthroscopic treatment of FAI syndrome. DESIGN AND SETTING: Cross-sectional research of quantitative and qualitative types using data obtained from July 2018 to October 2019. METHODS: A total of 58 patients of both genders diagnosed with FAI syndrome and who had undergone hip arthroscopy participated in this research. To establish reliability and validity, patients first answered the Brazilian versions of the 12-Item Short-Form Health Survey (SF-12), Nonarthritic Hip Score (NAHS), and HSAS; after a 48-hour interval, they answered the HSAS-Brazil again. RESULTS: For test-retest reliability, the interclass correlation was 0.908 (P < 0.001). The HSAS-Brazil correlated to the NAHS-Brazil (r = 0.63, P < 0.001), as well as the SF-12 (Physical Health) (r = 0.42, P = 0.001). CONCLUSION: The HSAS-Brazil was validated and proved to be a reliable and valid scale to assess sports activity levels in physically active patients with FAI syndrome after arthroscopic treatment.

16.
Cogitare Enferm. (Online) ; 28: e90288, Mar. 2023. tab
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1520782

ABSTRACT

RESUMO: Objetivo: avaliar a consistência interna de instrumentos utilizados no Brasil para mensuração de situações de violência contra pessoa idosa em dois estados. Método: estudo de corte transversal, desenvolvido com 481 idosos, em duas amostras, estados e recorte temporal diferentes. Foram aplicados dois instrumentos de mensuração de violência contra pessoa idosa. Os dados foram analisados, e a consistência interna entre os itens foi medida pelo coeficiente de Alfa de Cronbach. Resultados: o Hwalek-Sengstock Elder Abuse Screening Test apresentou o coeficiente de α = 0,08 para amostra coletada na Paraíba, enquanto, em Pernambuco, foi α = 0,57. A Conflict Tactics Scale apresentou alta precisão para definição da violência com coeficiente de α = 0,81 e α = 0,80 para as duas amostras. Conclusões: apenas a Conflict Tactics Scale apresentou-se confiável e estável para determinação da violência de natureza física e psicológica entre idosos, contribuindo assim, como uma possibilidade de desvelar o fenômeno.


ABSTRACT Objective: to evaluate the internal consistency of instruments used in Brazil to measure situations of violence against the elderly in two states. Method: a cross-sectional study with 481 elderly people in two different samples, states, and time periods. Two instruments were used to measure violence against the elderly person. The data was analyzed and the internal consistency between the items was measured by the Cronbach's alpha coefficient. Results: the Hwalek-Sengstock Elder Abuse Screening Test showed a coefficient of α = 0.08 for the sample collected in Paraíba, while in Pernambuco it was α = 0.57. The Conflict Tactics Scale was highly accurate in defining violence, with a coefficient of α = 0.81 and α = 0.80 for the two samples. Conclusions: only the Conflict Tactics Scale turned out to be reliable and stable for determining physical and psychological violence among the elderly, thus contributing as a way of uncovering the phenomenon.


RESUMEN Objetivo: Evaluar la consistencia interna de instrumentos utilizados en Brasil para medir situaciones de violencia contra ancianos en dos estados. Método: Estudio transversal realizado con 481 ancianos en dos muestras, estados y periodos de tiempo diferentes. Se utilizaron dos instrumentos para medir la violencia contra ancianos. Se analizaron los datos y se midió la consistencia interna entre los ítems mediante el coeficiente alfa de Cronbach. Resultados: el Hwalek-Sengstock Elder Abuse Screening Test presentó un coeficiente de α = 0,08 para la muestra recogida en Paraíba, mientras que en Pernambuco fue de α = 0,57. La Escala de Tácticas de Conflicto fue altamente precisa en la definición de violencia, con coeficientes de α = 0,81 y α = 0,80 para ambas muestras. Conclusiones: sólo la Escala de Tácticas de Conflicto demostró ser fiable y estable para determinar la violencia física y psicológica entre ancianos, contribuyendo así a desvelar el fenómeno.

17.
ABCS health sci ; 48: e023222, 14 fev. 2023. tab, ilus
Article in English | LILACS | ID: biblio-1516699

ABSTRACT

INTRODUCTION: The decline in functional capacity (FC) interferes with the functional independence of older adults, so it is important to assess the FC and use appropriate instruments for this. OBJECTIVE: To investigate the Glittre Activities of Daily Living (ADL) test's validity and reliability for assessing functional capacity in older adults. METHODS: Cross-sectional study with a sample of 100 elderly (68 ± 5.16 years). To assess the convergent validity, the Six-Minute Walk Test (6MWT) and the Timed Up and Go Test (TUG) were performed. The intra-examiner test-retest of the Glittre-ADL test was performed on the same day with a 30-minute interval between repetitions and inter-examiner reliability with an interval of seven days. RESULTS: There was a strong correlation between the Glittre-ADL test and the 6MWT (r=-0,75; p<0.001) and the TUG (r=0.77; p<0.001). The intra-examiner and inter-examiner reliability was excellent (ICC)=0.91 and 95% CI=0.14-0.97; p<0.001 and ICC=0.91; 95% CI: 0.86-0.94; p<0.001, respectively). CONCLUSION: The Glittre-ADL test demonstrated that it is valid and that its reliability is adequate to assess functional capacity in older adults.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Activities of Daily Living , Exercise , Health of the Elderly , Reproducibility of Results , Cross-Sectional Studies
18.
Rev. bras. ortop ; 58(1): 79-84, Jan.-Feb. 2023. tab, graf
Article in English | LILACS | ID: biblio-1441352

ABSTRACT

Abstract Objective To calculate the minimal important clinical difference (MICD) value for the Lysholm and International Knee Documentation Committee (IKDC) scores in a sample of patients submitted to anterior cruciate ligament reconstruction. Methods Primary, observational, retrospective, analytical study of participants submitted to anterior cruciate ligament reconstruction from March 2019 to December 2020 by the same surgeon, with a minimum follow-up of 6 months, analysis of knee function in the pre- and postoperative period by the Lysholm and IKDC scores, and answer to an anchor question at 6 months postoperatively for the calculation of the MICD of each score. Results A total of 59 patients participated in the study, with a mean age of 27.1 ± 5.7 years old. In the comparison between pre- and postoperative scores of all groups, there was an increase in values with statistical significance after intervention. The MICD was 5.5 for the Lysholm score, and the MICD value for the IKDC score could not be determined. Conclusion For the Lysholm score, the calculation of the MICD value by the anchor question method in the sample evaluated was 5.5. It was not possible to determine the value of the MICD for the IKDC score.


Resumo Objetivo Calcular o valor da mínima diferença clinicamente importante (MDCI) para os escores de Lysholm e International Knee Documentation Commitee (IKDC) na amostra de pacientes submetidos a reconstrução de ligamento cruzado anterior. Métodos Estudo primário, observacional, retrospectivo, analítico, de participantes submetidos a reconstrução do ligamento cruzado anterior no período de março de 2019 a dezembro de 2020, pelo mesmo cirurgião, com seguimento mínimo de 6 meses, análise da função do joelho no período pré e pós-operatório pelos escores de Lysholm e IKDC, e resposta a uma pergunta âncora aos 6 meses de seguimento pós-operatório, para o MDCI de cada escore. Resultados Participaram do estudo 59 pacientes, com média de idade de 27,1 ± 5,7 anos. Na comparação dos escores pré- e pós-operatórios de todos os grupos, observa-se aumento dos valores com significância estatística após a intervenção. A MDCI foi de 5,5 para o escore de Lysholm, não tendo sido possível determinar o valor para o IKDC. Conclusão O cálculo do valor da MDCI pelo método da pergunta âncora, na amostra avaliada, foi de 5,5 para o escore de Lysholm. Não foi possível determinar o valor da MDCI para o IKDC.


Subject(s)
Humans , Surveys and Questionnaires , Reproducibility of Results , Anterior Cruciate Ligament , Anterior Cruciate Ligament Reconstruction , Knee Joint
19.
Arq. neuropsiquiatr ; 81(1): 19-26, Jan. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429886

ABSTRACT

Abstract Background Spatial orientation is a cognitive domain frequently compromised in patients with Alzheimer disease (AD) and may be one of its first clinical manifestations. Some studies have shown that allocentric integration with egocentric spatial information seems to be impaired in this pathology. There is no consensus on how best to assess spatial orientation and traditional tests lack ecological validity, but, recently, virtual reality (VR) has provided new opportunities for this assessment. Objectives To analyze the applicability and stability of an immersive virtual task developed to assess spatial orientation, the Spatial Orientation in Immersive Virtual Environment Maze Test (SOIVET-Maze) in older adults with and without mild cognitive impairment. Methods Forty-three older adults were included in the study, 24 without cognitive impairment and 19 with mild cognitive impairment. Applicability was assessed by the Witmer and Singer Sense of Presence Questionnaire and a questionnaire for adverse events of cybersickness. To assess stability, participants were assessed twice with an interval of 7 to 14 days, and the intraclass correlation coefficient was calculated between visits. The t test or the Mann-Whitney test was used to compare applicability and stability between groups. Results There was no significant difference between the groups regarding applicability. A strong correlation between the first and second day of testing was found in the mild cognitive impairment group. Conclusion The SOIVET-Maze task showed excellent applicability and good stability, favoring its clinical application for the evaluation of spatial orientation in older adults.


Resumo Antecedentes A orientação espacial é um domínio cognitivo frequentemente comprometido em pacientes com doença de Alzheimer (DA) e pode ser uma das suas primeiras manifestações clínicas. Alguns estudos demonstraram que a integração alocêntrica com informações espaciais egocêntricas parece prejudicada nessa patologia. Não há um consenso sobre qual a melhor forma de avaliar a orientação espacial e os testes tradicionais carecem de validade ecológica; porém, recentemente, a realidade virtual (RV) proporcionou novas oportunidades para esta avaliação. Objetivos Analisar a aplicabilidade e estabilidade de uma tarefa virtual imersiva desenvolvida para avaliar a orientação espacial, o Spatial Orientation in Immersive Virtual Environment Maze Test (SOIVET-Maze) em idosos com e sem comprometimento cognitivo leve. Métodos Quarenta e três idosos foram incluídos no estudo, 24 sem comprometimento cognitivo e 19 com comprometimento cognitivo leve. A aplicabilidade foi avaliada pelo Witmer and Singer Sense of Presence Questionnaire e um questionário para eventos adversos de cybersickness. Para avaliar a estabilidade, os participantes foram avaliados 2 vezes com intervalo de 7 a 14 dias, e o coeficiente de correlação intraclasse foi calculado entre as visitas. O teste t ou o teste de Mann-Whitney foi utilizado para comparar a aplicabilidade e estabilidade entre os grupos. Resultados Não houve diferença significativa entre os grupos quanto à aplicabilidade. Uma forte correlação entre o primeiro e o segundo dia de teste foi encontrada no grupo de comprometimento cognitivo leve. Conclusão A tarefa SOIVET-Maze apresentou excelente aplicabilidade e boa estabilidade, favorecendo sua aplicação clínica para avaliação da orientação espacial em idosos.

20.
Acta Paul. Enferm. (Online) ; 36: eAPE01082, 2023. tab
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1439041

ABSTRACT

Resumo Objetivo Realizar a adaptação transcultural e validar o conteúdo do instrumento Kidney Transplant Understanding Tool para o cenário brasileiro. Métodos Estudo metodológico realizado na capital pernambucana, que executou cinco etapas de um protocolo canadense de adaptação transcultural. A versão pré-final do instrumento foi avaliada por 36 participantes em terapia renal substitutiva e sete especialistas em Nefrologia. Resultados Para cada item, atingiu-se o I-IVC ≥ 0,85; e 0,99 para a escala S-IVC/Ave em equivalência conceitual e de conteúdo. O teste binomial apresentou o p-valor ≥ 0,05 para todos os itens; e o Coeficiente de Concordância de Kappa foi de 0,90. Conclusão O instrumento adaptado foi considerado claro pelos participantes e o conteúdo foi validado pelos especialistas. O Kidney Transplant Understanding Tool (K-TUT-Br) foi validado para utilização no contexto do transplante renal no Brasil. A sua aplicação poderá instrumentalizar a enfermagem na implementação de mudanças estratégicas nas estruturas técnico-assistenciais em uso de práticas baseadas em evidências ressaltando o conhecimento e o Letramento em Saúde.


Resumen Objetivo Realizar la adaptación transcultural y validar el contenido del instrumento Kidney Transplant Understanding Tool para el escenario brasileño. Métodos Estudio metodológico realizado en la capital del estado de Pernambuco, donde se ejecutaron cinco etapas de un protocolo canadiense de adaptación transcultural. La versión preliminar del instrumento fue evaluada por 36 participantes en terapia de reemplazo renal y siete especialistas en Nefrología. Resultados En cada ítem se alcanzó el I-IVC ≥ 0,85; y 0,99 en la escala S-IVC/Ave en equivalencia conceptual y de contenido. La prueba binominal presentó el p-valor ≥ 0,05 en todos los ítems; y el coeficiente de concordancia de Kappa fue de 0,90. Conclusión El instrumento adaptado fue considerado claro por los participantes y el contenido fue validado por los especialistas. El Kidney Transplant Understanding Tool (K-TUT-Br) fue validado para su utilización en el contexto del trasplante renal en Brasil. Su aplicación podrá servir de instrumento para enfermeros en la implementación de cambios estratégicos en las estructuras técnico-asistenciales en uso de prácticas basadas en evidencia, destacando el conocimiento y la alfabetización en salud.


Abstract Objective To perform a cross-cultural adaptation and content validation of the Kidney Transplant Understanding Tool for the Brazilian context. Methods A methodological study conducted in the city of Pernambuco, Brazil, which performed the five steps of a Canadian cross-cultural adaptation protocol. The pre-final version of the instrument was evaluated by 36 participants in renal replacement therapy and seven specialists in nephrology Results For each item, the Item Content Validity Index - I-CVI ≥ 0.85 was achieved; and 0.99 for the mean Scale Content Validity Index - S-CVI/Ave in conceptual and content equivalence. The binomial test showed a p-value ≥ 0.05 for all items; and the Kappa Coefficient of Agreement was 0.9. Conclusion The adapted instrument was found to be clear by the participants, and the content was validated by the experts. The Kidney Transplant Understanding Tool (K-TUT-Br) was validated for use in the context of kidney transplantation in Brazil. Its application may enable nurses to implement of strategic changes in technical and care structures using evidence-based practices focusing on knowledge and health literacy.

SELECTION OF CITATIONS
SEARCH DETAIL